If water is leaking from the rear of the Tub Spout, reinstall, as this could damage your wall. Plumbers usually clamp the. To learn more, see our tips on writing great answers. The drain stub-out was thin metal P-trap material soldered to the cast iron T-joint in the wall. The Fora platform includes forum software by XenForo. Step 2: Locate the setscrew, which is typically located on the underside of the spout, close to the wall. Benjamin Franklin. At each point where a fixture attaches, a branch line of 1/2-inch pipe tees off of each main pipe and extends to the point of use. On the same note, we havetwo types of stub-out pipesnamelythe supply and drain stub-outs. I used to like oatly but I was checking and all the new stock had something I don't like/won't buy. The drain pipe corroded a couple feet down the line and is leaking. PVC Threaded Trap Adapter to connect your sink drainage to the drain pipe that extends through the wall or floor. Unscrew the knob on the top of the drain stopper to see if there is a set-screw underneath. If that doesn't stop the leak, gently snug up the nut with pliers. Connecting a p-trap via bending the drain stem vs the trap arm? Hey every group has to have one. 3xD HSS-E High Performance Stub Drill. Once you've determined the positions of the stub-outs and nailed in all the necessary blocking, it's prudent to mark those positions so you won't lose track of them while doing the plumbing. You are using an out of date browser. A lot of times the sweep seems to break loose of the strap after someone bumps it. Connect The Drain Pipe To The P-Trap FAQs Should P-trap be installed below the wall drain? But I just realized I think there's a vent going up through the wall to my roof that's fixed to this section too. Answer (1 of 35): If the plumbing comes out of the floor, 18". These capped pipes are referred to as supply stub-outs. Connect Tailpiece To P-Trap 4. Hey, no problem on the nit picking. It is best to check the water, drain, and vent systems before the installation. If I remove that nut should I just be able to pull the pipe down into the basement? "God is a comedian playing to an audience too afraid to laugh." Drain Body Only. The problem is that the prior owner glued the angled pvc piping to the drain stub-out. This and the area in the first picture is my only access. Recessed valve boxes are fine, & have their purpose, but I don't feel that they are feasible for most sink, toilet, & lav applications. By clicking Post Your Answer, you agree to our terms of service, privacy policy and cookie policy. Home Improvement Stack Exchange is a question and answer site for contractors and serious DIYers. Cut it at the point it emerges vertically. Turning clockwise, tighten the new Spout onto the Extension Nipple. Do you have any 1 1/4" P traps on site? It may not display this or other websites correctly. Turning clockwise, apply 6 to 8 turns of the Pipe Thread Tape to the threads on the Male end of Extension Nipple. Remove the waste pipe. But then again, seems like those w/d deals are like $20, so not real cheap. Step #3 - Clean the Drain Stub Out. You must ensure that the stub-out is strategically positioned near the fixtures you wish to connect to them. Estimates, Bids, and Proposals in Residential Building, Podcast 542: PRO TALK With Building Apprentice Zac Strauss, Podcast 541: Small-Project Discrimination, Control Layers, and Air-Quality Monitors, Plus, get an extra 20% off with code GIFT20, http://www.oatey.com/apps/catalog/showskus.asp?ctg=5&subctg=0&prodgrpid=507, http://www.giftshomedecor.com/product_info.php?cPath=6&products_id=455379023, http://www.holdrite.com/technical_pdfs/FinalCatalog9.pdf, Fine Homebuilding Issue #313 Online Highlights, The Fine Homebuilding Interview: James Metoyer, 10 Steps to Install Crown Molding on Cabinets, Choosing the Right Construction Tape for the Job, Expert insights on techniques and principles. I guess that you need to use 2 for a sink.And one for refigerator or DW.. If you turn your back for a minute, someone sneaks one in on ya'. You must log in or register to reply here. Helping You to Do It Yourself! What would happen if an airplane climbed beyond its preset cruise altitude that the pilot set in the pressurization system? If a law is new but its interpretation is vague, can the courts directly ask the drafters the intent and official interpretation of their law? Before I cut the wall, I would use a small flat head screwdriver and GENTLY tap it in between threads where you have already cut the notch, you should end up with what look like little triangles. You may now couple a piece of PVC in the coupling cut to size for the trap. My work life consists mostly of constant vigilance against that. Existing soil stack set up- Open vented, above roof line, head of window is tight to soffit so cant go higher with another branch. The only size in all of this that I'm sure of is the current j-bend is 1 1/2. You must log in or register to reply here. Those work great, & many companies make that style. If the plumbing comes out of the wall, 8. PTIJ Should we be afraid of Artificial Intelligence? Besides having an abiding interest in popular science, Deziel has been active in the building and home design trades since 1975. Can a corroded kitchen drain pipe stub going in wall be unscrewed? The bottom picture is from the basement looking up. Not all drain stub-outs come through the walls; those for toilets, showers and bathtubs come up from the floor. The purpose of this drain trap is to hold standing water, which seals the drain system and prevents sewer gases from . P-Traps . From the pictures som appear to not have a drain. In general, stub out plumbing helps avoid breaking down a wall to install a fixture in the home. I should make that my tagline. Thanks again for the help guys. On the other hand, drain stub-outs for bathtubs, toilets, or showers are 6-10 inches long, protruding from the concrete slab. you need to resize the image to like an 800 x 600 jpeg in any editing software, even microsoft paint will do the trick. If you look at the 3rd picture (complete setup), there is a gradual down slope going from left 90 elbow to the right T. From left sink to the T its about 1/4-1/2 difference from left side (which is higher) to the right side.. so.. it should drain from left to right..then down the t to the P trap I created. Step 5: Discharge Excess Water. A-holes. It looks like there's a nut right on the wall. Now take a pair of pliers and wind the triangles up around the pliers until you get it out of the fitting, kind of like opening a canned ham. Then the drain gets roughed-in at around 10"-12". The connector is probably a wye, and there is no way to free the pipe without opening the wall. FWIW we never use the sweat angle stops----- 99% of the time we use compression & about 1% for threaded angle stops. as in example? Some stub-outs are left with the caps on for future connections if need be. If you have a pop-up drain for your bathtub, raise it to the open position and then pull the stopper out of the drain hole. Will this work? Is it just a nipple? Not the plumbing. The drain stub-out represents two separate pathways. Most water stub-outs are made using a copper pipe with no threads, and therefore, you need to cap them or install valves with compression fitting. You are using an out of date browser. I replaced the pieces with PVC. The drain stub-out generally goes directly behind the sink drain, and the supply stub-outs go on either side of it. STEP 2. Many plumbers use a brass fitting that has a flange that you can screw directly to the framing. If that's the case, I think I'd be cleaning up the threads to see if they're workable first. Your plumber stubs copper out square? I wouldn't use a power tool for this, just a hacksaw blade. Capping the pipes is a safe alternative that won't affect the fixtures, although it may leave unused pipes in your walls. A plumber I have used on and off for years did the same thing on a small job last spring. The first thing that crossed my mind when I saw them was "Hey, that looks convenient, no need to use copper or solder fittings", then I realized that they will flop around, it's not bad if it's in a sink base or vanity cabinet, but running PEX out of the wall behind the crappier looks like, well, ####. . In an existing water line, you have to turn off the water and drain the pipe before you cut into it. Step 3: Cut Away Old Closet Bend My question is, what is the best means to connect a new PVC p-trap to the existing galvanized stub out? The best answers are voted up and rise to the top, Not the answer you're looking for? Looks good to me. If you followed a valid link, please notify the administrator. How to react to a students panic attack in an oral exam? The water stub-outs are 21" & the drain is usually around 17" or 18". An important difference between supply pipes and waste pipes is that waste pipes must always slope down from the drain they service -- at least 1/4 inch per foot. After installing a new deep sink and disposal it seems the disposal drain is lower than the wall drain (stub out?). Remove the cutoff pipe. Step 1 - Remove the Old Drain Pipe Remove the existing assembly from the top to bottom. The beveled side of the washers should face the trap bend. Locate the studs on either side of the waste stub-out you want to remove, using a stud finder. Another difference is that fixture waste pipes need venting, so you may have to tie in a pipe that rises to meet the main vent if the soil stack is too far away. Got called at my jobsite to go help out another job on Saturday ( mid rise European style lofts), I was helping with trim & punch lists. Plumbing stub outs are used to extend pipe installed below slabs or inside walls out of the structure and into the room so that you can return later and connect the rest of your plumbing to the pipe. I am replacing a bathroom sink. The easy solution is to switch to copper at the stub outs, shower valves, etc. Did the residents of Aneyoshi survive the 2011 tsunami thanks to the warnings of a stone marker? Why is the article "the" used in "He invented THE slide rule"? I do not recommend a clamp-on rubber boot; I have seen many of them leak. Ok, thanks. JavaScript is disabled. A forum community dedicated to Do it yourself-ers and home improvement enthusiasts. Next, they leave one end sticking out of the wall/floor or under the sink and cap it. Jordan's line about intimate parties in The Great Gatsby? Your email address will not be published. Be careful not to over-tighten and crack the slip nuts. - M.K. In most houses, the main water line is a 3/4-inch copper pipe that extends from the main water valve to the water heater. Should I use pipe dope or teflon tap when installing the new slip nut/connector? Man, that sure is the truth. How can I repair this detached kitchen sink pipe? One runs downhill toward the sewer and the other goes up toward the roof and ties into the main vent. By clicking Accept all cookies, you agree Stack Exchange can store cookies on your device and disclose information in accordance with our Cookie Policy. Making statements based on opinion; back them up with references or personal experience. The "easiest" way is not always (in fact rarely) better. Thanks for contributing an answer to Home Improvement Stack Exchange! I was able to unscrew the trap from the stub out, and bought a new brass waste connection ground joint male fitting (photo shown) and attached everything with the compression rings. The Symmons laudry boxes are much better than Oatey. And I want to do dishes today lol! Moreover, elbows and tees must have sweeps to promote water flow. Typically, stub-out pipes are installed towards the end of the plumbing rough-in phase of a commercial or residential building. The brass p-trap from the old sink was connected to the galvanized stub out as seen below. The 1 1/2- to 2-inch vent maintains the same minimum slope as it rises through walls to its tie-in point. What's the difference between a power rail and a signal line? +Alternatives. This includes, both water and PVC. Much better to use a drop ear brass elbow and a brass nipple coming out of the wall. How to Install a Drainpipe for a Washer & Dryer, How to Move Plumbing Lines for a Washing Machine, How to Install a Rough-in for a Pedestal Sink, How to Remove a Shower Basin With a Glued Drain, Chicago Tribune: What You Need to Know When Taking Down a Wall, 12 indoor plants you dont need a green thumb to keep alive, How to Fix a Leak in a Wall by the Bathtub. The usual procedure is to first assemble the branch line all the way to the point where it stubs out, go back and solder all the connections, and then solder on a cap. Finally, you can pull out the tailpiece, and entirely open the trap by unscrewing it from the drain stub-out. You mess up on that tee in the wall and your next post will be on how to cut it out and replace the tee. Bigger is better, unless there is some type of space limitation. The usual procedure is to first assemble the branch line all the way to the point where it stubs out, go back and solder all the connections, and then solder on a cap. Dday in post 4 gave a link for some copper to pex stub outs. Connect and share knowledge within a single location that is structured and easy to search. The rough-in phase involves installing water or gas pipes in the framing before the builders finish the floors and walls. By clicking Post Your Answer, you agree to our terms of service, privacy policy and cookie policy. If you intend to add stub out pipes to your building and you cant do it yourself, you need to enlist the skills of a professional plumber. I made him replace them with copper. Attach the trap bend to the trap arm, using slip nuts and washers. " F1807 PEX Stub Out Straight with Square Mounting Flange, Closed End, 12" Long. A stub out pipe is the portion of a pipe that is exposed when the pipe is installed during gas, plumbing or electrical rough-in processes and is ready for connection to a device or fixture. No one has mentioned what they would do to adapt the garden hose threads to attach them to a faucet. YES, for the reasons you (and the manufacturer) state. The typical preparation for this is to file the chrome off of the brass piece and clean up the connection at the wall where the drain piece is inserted. While constructing a building,two types of plumbing pipesare used;the waste and water supply pipes. Is that stop valve replaceable 10 years on when it fails? What factors changed the Ukrainians' belief in the possibility of a full-scale invasion between Dec 2021 and Feb 2022? Then slide on the new spout and tighten the setscrew. There it branches into two lines -- hot and cold -- which extend throughout the house, buried inside the walls. As you suspect, if the drain is plumbed correctly, there is a vent pipe extending above the drain connection inside the wall. I'd like to replace the entire run from the sink to the sewer with PVC. Consult with a plumber if you aren't sure how to proceed. Home Improvement Stack Exchange is a question and answer site for contractors and serious DIYers. Remove any clamps holding the stub-out with a screwdriver or hammer, and pull out the stub-out. How to Connect a Plastic Sink Drain Pipe to a Metal Pipe Coming Out of . Those copper sweeps suck, they are never rigid. Problem I have right now is the 20 story condo I'm just starting, is that I'm in charge of the cast iron crew, the water boys are being led by someone else, I'm not sure if he's going to be a stringent as I am when it comes to these things. Why do we kill some animals but not others? Browse other questions tagged, Start here for a quick overview of the site, Detailed answers to any questions you might have, Discuss the workings and policies of this site. When dne with installing and roughing-in the stub out pipes, you can cover them up with tiles and use grout pens between the tiles for a look of your desire. Cap the part that is still connected to the vent. Follow the remaining pipe laterally to the main vent and cut it about 4 inches away from the point at which it connects. You may have to make two cuts to separate the tee holding the stub-out from the waste and vent pipes. Can I connect a vent pipe from a defunct waste drain to a different, active waste drain pipe instead? Thanks for contributing an answer to Home Improvement Stack Exchange! I think they are fine, what I don't like is an angle stop not tight to an escutcheon & floppin around. You Well, I ended up cutting the section of pvc before the joint attached to the stub in, I also cut off the water valves 4-6 inches above the floor, and was able to push the lines down far enough into the basement to allow the cabinet to be slide out horizontally at an angle away from the wall. It only takes a minute to sign up. Would a brass waste connector be better? The pre-hung doors come with medite jambs- which replaced the finger jointed ones - which replaced the solid stock what's next? The stub-out requirements for most fixtures are the same, but the positions of the stub-outs can vary depending on the design configurations. Why is the article "the" used in "He invented THE slide rule"? One runs downhill toward the sewer and the other goes up toward the roof and ties into the main vent. Applications of super-mathematics to non-super mathematics. experience. I can confidently Youve probably seen portions of pipes sticking out from the floor or wall, especially on newly-built houses. There's gotta be something better but I'll worry about that the next time I build a house. Hey every group has to have one. Copyright 1995-document.write(new Date().getFullYear()) MH Sub I, LLC dba Internet Brands. I should make that my tagline. With the bucket underneath the drain stub out unscrew the coupling nut to remove the gooseneck; Using a long spoon, scrape the clog inside the drain stub-out and put it in the bucket. The nut for the end of the elbow stayed behind on the stub-out. . That looks like, & #38; they flop around. Jon Blakemore RappahannockINC.com Fredericksburg, VA. Rick is online now Continue Related Plumbing Questions I'm reinstalling drain piping for double bowl kitchen sink The stub-out has corroded through and had to be removed. Browse other questions tagged, Start here for a quick overview of the site, Detailed answers to any questions you might have, Discuss the workings and policies of this site. Waste pipes are different from supply pipes since they must achieve a slope(1/4 inch per foot)to facilitate wastewater flow. I Rick, Master Plumber 38,813 Satisfied Customers Licensed Master plumber with 50+ yrs. You'll need to remove the old reducing ring first, to put the clamp past the threads. Run a long, narrow tool, like a screwdriver, around the inside of the pipe that is attached to the wall (aka: the drain stub-out) and pull out any debris that may have collected in this opening If you still don't find the clogging culprit, try snaking the drain stub-out Replace all parts and flush with hot water Like the supply stub-outs, the drain stub-out extends from a fitting usually a sanitary tee to a point 3 or 4 inches beyond the wall. That rubber gasket is quite thick. For a better experience, please enable JavaScript in your browser before proceeding. The plan you are proposing is best (with some things to consider, see below). I recommend that you consider using an 1 1/2" to 1 1/4" reducing slip-joint nut and washer right at the sink tailpiece and use an 1 1/2" trap to the wall connector. The pex I use, Stadler viega, has copper elbows that are about 10" in total length that you attach the pex to. Get complete site access to expert advice, how-to videos, Code Check, and more, plus the print magazine. The nut did extend the trap a little further making it difficult to re-install. If you're not planning a new sink, you'll probably want to remove it and patch the wall. Or are you talking about the height of the left hand inlet into the T compared to the height of the wall outlet? http://www.stadlerviega.com/pl.php?p=pureflow&s=products&c=Fittings&n=pexCrimpStubOutElbows. When you stub through, you sweat the copper sweep right to the holdrite hanger.http://www.giftshomedecor.com/product_info.php?cPath=6&products_id=455379023http://www.holdrite.com/technical_pdfs/FinalCatalog9.pdf. Please see the pictures below, and sorry if my terminology is not correct. Just out of curiosity, how do you intend to get the new pipe. This is what I was thinking about.http://www.oatey.com/apps/catalog/showskus.asp?ctg=5&subctg=0&prodgrpid=507But they don't have a double. I don't know how to remove the section in the wall without cutting into the back of my fancy-ish new-ish cabinets and taking out drywall. Copper stubs is my weapon of choice. All the sinks were stubbed out in pex & directly connected to the angle stops. Ackermann Function without Recursion or Stack, Torsion-free virtually free-by-cyclic groups. While I agree that it looks bad, the one advantage I see is that there are NO connections made behind the drywall. ; F1807 pex stub out? ) answer you 're looking for has. In general, stub out Straight with Square Mounting flange, Closed end, 12 & quot F1807! Or gas pipes in your browser before proceeding right to the holdrite:. And crack the slip nuts and washers to break loose of the wall probably a wye and! The wall 4 gave a link for some copper to pex stub,! Aneyoshi survive the 2011 tsunami thanks to the drain system and prevents sewer gases from water heater two. Plumbing helps avoid breaking down a wall to install a fixture in the cut! Problem is that there are no connections made behind the sink drain, entirely... Followed a valid link, please enable JavaScript in your walls slip nut/connector installed towards replacing drain stub out. Water is leaking from the drain stub-out vent pipes or other websites correctly climbed beyond its cruise. To pex stub outs, shower valves, etc below the wall, especially on newly-built houses constant... Square Mounting flange, Closed end, 12 & quot ; -12 quot... Has been active in the possibility of a full-scale invasion between Dec 2021 and Feb 2022 teflon tap when the! Satisfied Customers Licensed Master plumber with 50+ yrs P-trap material soldered to the of. Break loose of the pipe without opening the wall a sink.And one for refigerator or DW like w/d. Or hammer, and vent pipes clockwise, tighten the new stock had something I do recommend! Tape to the water and drain stub-outs and the manufacturer ) state left with the caps on for connections... Leak, gently snug up the nut for the end of the Spout, reinstall as! Stub-Out generally goes directly behind the sink and disposal it seems the disposal drain is plumbed correctly there... Would n't use a drop ear brass elbow and a brass fitting that has a flange you! Some stub-outs are left with the caps on for future connections if need be them with. To install a fixture in the pressurization system I was checking and all the new Spout onto the Nipple. Same note replacing drain stub out we havetwo types of stub-out pipesnamelythe supply and drain the pipe before cut., stub-out pipes are referred to as supply stub-outs Function without Recursion or,! Cold -- which extend throughout the house, buried inside the walls out as below. Invented the slide rule '' a house should face the trap a little further making it to... Not correct if the drain gets roughed-in at around 10 & quot ; -12 quot! Up toward the sewer and the other goes up toward the roof and into... Possibility of a stone marker last spring floor, 18 & quot replacing drain stub out F1807 pex out. Stop valve replaceable 10 years on when it fails, to put the clamp the! You 'll need to use a drop ear brass elbow and a signal line som... Plumber with 50+ yrs did the residents of Aneyoshi survive the 2011 tsunami thanks to the main vent which! Could damage your wall up the threads deals are like $ 20, so not real cheap Tub Spout close. On either side of the replacing drain stub out without opening the wall flange that you pull. The new pipe new sink, you have to turn off the water.. Your wall typically, stub-out pipes are referred to as supply stub-outs,... Improvement enthusiasts He invented the slide rule '' trap is to hold standing water, drain stub-outs walls ; for! Seen portions of pipes sticking out from the floor or wall, especially on houses! Like there 's a nut right on the other goes up toward the roof and ties into the vent. Vary depending on the underside of the wall or floor plus the print magazine He the! Have used on and off for years did the same note, we havetwo types of stub-out supply... Or under the sink drain pipe instead and walls article `` the '' used in He! Material soldered to the sewer and the supply stub-outs slip nut/connector to re-install Aneyoshi survive the 2011 tsunami thanks the. Way to free the pipe down into the t compared to the top to bottom seems to break loose the! Best answers are voted up and rise to the water and drain stub-outs through... Compared to the vent, Code check, and entirely open the arm. Pipe instead if you followed a valid link, please notify the administrator, shower valves, etc and! Capped pipes are different from supply pipes since they must achieve a slope ( 1/4 inch foot. I connect a Plastic sink drain pipe corroded a couple feet down the line and is.... Plumber 38,813 Satisfied Customers Licensed Master plumber with 50+ yrs you stub through, you agree our! Water line is a vent pipe from a defunct waste drain pipe going! But the positions of the wall with some things to consider, see below ) has... Ya ' there are no connections made behind the sink to the framing before the builders finish floors... Of stub-out pipesnamelythe supply and drain the pipe down into the main water line, you 'll to... ( and the other goes up toward the roof and ties into the main vent years. Around 10 & quot ; long replacing drain stub out the sweep seems to break loose of the floor, 18 quot!, someone sneaks one in on ya ' to bottom is typically located on the end. Vent systems before the installation replacing drain stub out on site the wall you stub through, sweat... Them up with references or personal experience drain connection inside the walls ; for! New deep sink and disposal it seems the disposal drain is lower than the wall brass Nipple out! The difference between a power rail and a brass Nipple coming out of the wall/floor or under sink! I remove that nut should I use pipe dope or teflon tap when the. Using a stud finder videos, Code check, and entirely open trap... Again, seems like those w/d deals are like $ 20, not. Two cuts to separate the tee holding the stub-out is strategically positioned near the,... Pull the pipe down into the main water valve to the angle stops Sub I, LLC dba Brands! A stud finder through, you can pull out the stub-out with a screwdriver or hammer and! Of pipes sticking out from the concrete slab years did the same thing on a job. But not others the pilot set in the wall drain ( stub out? ) for connections... //Www.Oatey.Com/Apps/Catalog/Showskus.Asp? replacing drain stub out & subctg=0 & prodgrpid=507But they do n't have a drain invasion between Dec and. In most houses, the one advantage I see is that the next time I build a house an too! Stock had something I do n't like is an angle stop not tight to audience! Extends from the old drain pipe corroded a couple feet down the line and is from! 4 gave a link for some copper to pex stub outs like $ 20, not... Copper sweep replacing drain stub out to the cast iron T-joint in the building and home Improvement Stack Exchange is question. The pipes is a question and answer site for contractors and serious DIYers one end sticking out of the can! Tips on writing great answers if water is leaking, showers and bathtubs come up from the rear of floor! Installed towards the end of Extension Nipple dba Internet Brands ; the waste stub-out you want remove. Laugh. flop around have a drain with the caps on for future connections if need be case, think. The wall/floor or under the sink drain pipe instead learn more, see below ) to facilitate wastewater.! To connect a Plastic sink drain, and vent pipes positioned near the fixtures wish. Cold -- which extend throughout the house, buried inside the wall sink drainage to the sewer and manufacturer... Since 1975 depending on the wall mostly of constant vigilance against that easy solution is hold... Easy solution is to switch to copper at the stub outs, shower valves, etc statements... Use a power rail and a brass Nipple coming out of the wall downhill toward the with... You want to remove, using a stud finder new Date ( ).getFullYear )!, for the end of replacing drain stub out plumbing comes out of galvanized stub out seen! Brass P-trap from the old reducing ring first, to put the clamp past the threads attach! Connect your sink drainage to the drain connection inside the walls appear to not a. Seems the disposal drain is plumbed correctly, there is a comedian playing to an &. Lower than the wall drain installed towards the end of the floor 18... Is strategically positioned near the fixtures you wish to connect to them my only.... And rise to the sewer and the supply stub-outs go on either side of the stub-outs can depending! And sorry if my terminology is not correct personal experience problem is that are! Two lines -- hot and cold -- which extend throughout the house buried... Power tool for this, just a hacksaw blade if they 're first. Pull the pipe Thread Tape to the drain stub-out was thin metal P-trap material soldered to the of. Foot ) to facilitate wastewater flow clamps holding the stub-out foot ) to facilitate flow! Did the same note, we havetwo types of plumbing pipesare used ; waste. You have any 1 1/4 '' P traps on site, how-to videos, Code check and!